The Sellmeier equation is an empirical relationship between refractive index and wavelength for a particular transparent medium. The equation is used to determine the dispersion of light in the medium.
It was first proposed in 1872 by Wolfgang Sellmeier and was a development of the work of Augustin Cauchy on Cauchy's equation for modelling dispersion.[1]
The equation
In its original and the most general form, the Sellmeier equation is given as
- ,
where n is the refractive index, λ is the wavelength, and Bi and Ci are experimentally determined Sellmeier coefficients. These coefficients are usually quoted for λ in micrometres. Note that this λ is the vacuum wavelength, not that in the material itself, which is λ/n. A different form of the equation is sometimes used for certain types of materials, e.g. crystals.
Each term of the sum representing an absorption resonance of strength Bi at a wavelength √Ci. For example, the coefficients for BK7 below correspond to two absorption resonances in the ultraviolet, and one in the mid-infrared region. Close to each absorption peak, the equation gives non-physical values of n2 = ±∞, and in these wavelength regions a more precise model of dispersion such as Helmholtz's must be used.
If all terms are specified for a material, at long wavelengths far from the absorption peaks the value of n tends to
where εr is the relative permittivity of the medium.
For characterization of glasses the equation consisting of three terms is commonly used:[2][3]
As an example, the coefficients for a common borosilicate crown glass known as BK7 are shown below:
Coefficient | Value |
---|---|
B1 | 1.03961212 |
B2 | 0.231792344 |
B3 | 1.01046945 |
C1 | 6.00069867×10−3 μm2 |
C2 | 2.00179144×10−2 μm2 |
C3 | 1.03560653×102 μm2 |
For common optical glasses, the refractive index calculated with the three-term Sellmeier equation deviates from the actual refractive index by less than 5×10−6 over the wavelengths' range[4] of 365 nm to 2.3 μm, which is of the order of the homogeneity of a glass sample.[5] Additional terms are sometimes added to make the calculation even more precise.
Sometimes the Sellmeier equation is used in two-term form:[6]
Here the coefficient A is an approximation of the short-wavelength (e.g., ultraviolet) absorption contributions to the refractive index at longer wavelengths. Other variants of the Sellmeier equation exist that can account for a material's refractive index change due to temperature, pressure, and other parameters.
Coefficients
Material | B1 | B2 | B3 | C1, μm2 | C2, μm2 | C3, μm2 |
---|---|---|---|---|---|---|
borosilicate crown glass (known as BK7) | 1.03961212 | 0.231792344 | 1.01046945 | 6.00069867×10−3 | 2.00179144×10−2 | 103.560653 |
sapphire (for ordinary wave) | 1.43134930 | 0.65054713 | 5.3414021 | 5.2799261×10−3 | 1.42382647×10−2 | 325.017834 |
sapphire (for extraordinary wave) | 1.5039759 | 0.55069141 | 6.5927379 | 5.48041129×10−3 | 1.47994281×10−2 | 402.89514 |
fused silica | 0.696166300 | 0.407942600 | 0.897479400 | 4.67914826×10−3 | 1.35120631×10−2 | 97.9340025 |
Magnesium fluoride | 0.48755108 | 0.39875031 | 2.3120353 | 0.001882178 | 0.008951888 | 566.13559 |
See also
References
Internal links
- RefractiveIndex.INFO Refractive index database featuring Sellmeier coefficients for many hundreds of materials.
- A browser-based calculator giving refractive index from Sellmeier coefficients.
- Annalen der Physik - free Access, digitized by the French national library
- Sellmeier coefficients for 356 glasses from Ohara, Hoya, and Schott